Home · Science · Fluid Mechanics · Y+ Calculator

Y+ Calculator

Wall y+ for CFD meshes: friction velocity from a flat-plate skin-friction estimate, then y+ at a given wall distance.

Your figures

Example result — edit the figures to make it yours

213.88

y+

Computed from the inputs on this page with the formula below — change any figure and every result updates.

Friction velocity u_τ0.21 m/s
Skin-friction coefficient Cf0.00

What this calculator does

Wall y+ for CFD meshes: friction velocity from a flat-plate skin-friction estimate, then y+ at a given wall distance. Where a measure is involved, US and metric units are both accepted — flip the unit toggle and the figures convert with the same definitions the formula uses. Every result on this page is computed from the formula stated below, with no hidden rounding steps.

The formula and method

C_f = 0.058 · Re^(−0.2); τ_w = C_f · ½ρv²; u_τ = √(τ_w/ρ); y+ = u_τ · y / ν

Skin friction uses the stated flat-plate estimate Cf = 0.058·Re^(−0.2) for turbulent flow.

y+ below about 1 resolves the viscous sublayer; wall-function meshes usually target y+ between 30 and 300.

Worked example

With the example inputs this page opens with (free-stream velocity (m/s) 5, density (kg/m³) 1000, wall distance y (m) 0.001, kinematic viscosity ν (m²/s) 0.000001), the result is 213.88 — y+. Computed from the inputs on this page with the formula below — change any figure and every result updates.

Quick reference

Quick reference — varying free-stream velocity (m/s)
Free-stream velocity (m/s)y+
2.5106.94
4171.10
5213.88
6.25267.35
7.5320.82
10427.76

Computed with the same formulas as the calculator above — enter any values there for figures beyond this table.

Common questions

What y+ should my mesh have?

It depends on the wall treatment: low-Re (resolved) models want the first cell at y+ ≈ 1, while standard wall functions want 30–300 and perform badly in between, in the buffer layer.

Is the flat-plate Cf valid for pipes and airfoils?

Only as an estimate. It gives a sensible first-cell size before meshing; the solved CFD field's own y+ report is the figure to trust afterwards.

How does the Y+ Calculator work?

Wall y+ for CFD meshes: friction velocity from a flat-plate skin-friction estimate, then y+ at a given wall distance. Velocity · Density · Distance · Viscosity · Reynolds → y+. The result updates as you type, and the formula and method on this page state the exact definitions used, so you can reproduce the calculation by hand.

What inputs does the Y+ Calculator need?

Velocity · Density · Distance · Viscosity · Reynolds → y+. Invalid entries — such as a zero denominator, an out-of-range value or a malformed list — produce a plain-language message instead of a misleading number.