Home · Science · Fluid Mechanics · Broad Crested Weir Calculator
Broad Crested Weir Calculator
Flow over a broad-crested weir from crest width and upstream head, using the standard Cd·b·H^1.5·√g form.
What this calculator does
Flow over a broad-crested weir from crest width and upstream head, using the standard Cd·b·H^1.5·√g form. Where a measure is involved, US and metric units are both accepted — flip the unit toggle and the figures convert with the same definitions the formula uses. Every result on this page is computed from the formula stated below, with no hidden rounding steps.
The formula and method
Standard form used: Q = Cd · b · H^(3/2) · √g, with H the head above the crest and g = 9.80665 m/s².
Cd near 0.6 is typical for a broad crest with a square upstream corner; rounded entries run higher.
Worked example
With the example inputs this page opens with (discharge coefficient cd 0.6, crest width b (m) 3, head above crest h (m) 0.5), the result is 1.99 m³/s — flow rate. Computed from the inputs on this page with the formula below — change any figure and every result updates.
Quick reference
| Discharge coefficient Cd | Flow rate |
|---|---|
| 0.3 | 1.00 m³/s |
| 0.48 | 1.59 m³/s |
| 0.6 | 1.99 m³/s |
| 0.75 | 2.49 m³/s |
| 0.9 | 2.99 m³/s |
| 1.2 | 3.99 m³/s |
Computed with the same formulas as the calculator above — enter any values there for figures beyond this table.
Common questions
What head should I measure?
The depth of the upstream water surface above the crest, measured far enough upstream that the surface is level and the drawdown curve has not started.
Why the 1.5 power of head?
Both the flow area over the crest and the velocity grow with head — area linearly, velocity with its square root — multiplying to H^1.5.
How does the Broad Crested Weir Calculator work?
Flow over a broad-crested weir from crest width and upstream head, using the standard Cd·b·H^1.5·√g form. Cd · Crest width · Head → Flow rate. The result updates as you type, and the formula and method on this page state the exact definitions used, so you can reproduce the calculation by hand.
What inputs does the Broad Crested Weir Calculator need?
Cd · Crest width · Head → Flow rate. Invalid entries — such as a zero denominator, an out-of-range value or a malformed list — produce a plain-language message instead of a misleading number.