Home · Science · Heat & Thermodynamics · Virtual Temperature Calculator
Virtual Temperature Calculator
Virtual temperature of moist air: the temperature dry air would need to have the same density, Tv = T(1 + 0.61q), with q the specific humidity in g/kg.
What this calculator does
Virtual temperature of moist air: the temperature dry air would need to have the same density, Tv = T(1 + 0.61q), with q the specific humidity in g/kg. Where a measure is involved, US and metric units are both accepted — flip the unit toggle and the figures convert with the same definitions the formula uses. Every result on this page is computed from the formula stated below, with no hidden rounding steps.
The formula and method
Moist air is less dense than dry air at the same temperature because water molecules are lighter; the virtual temperature folds that effect into a temperature: T_v = T(1 + 0.61q).
The specific humidity q is entered in g/kg and divided by 1000. The temperature is entered in °C and converted to kelvin before applying the formula.
Worked example
With the example inputs this page opens with (air temperature t (°c) 25, specific humidity q (g/kg) 10), the result is 299.97 K — virtual temperature. Computed from the inputs on this page with the formula below — change any figure and every result updates.
Quick reference
| Air temperature T (°C) | Virtual temperature |
|---|---|
| 12.5 | 287.39 K |
| 20 | 294.94 K |
| 25 | 299.97 K |
| 31.25 | 306.26 K |
| 37.5 | 312.54 K |
| 50 | 325.12 K |
Computed with the same formulas as the calculator above — enter any values there for figures beyond this table.
Common questions
Why is virtual temperature always at least the real temperature?
Water vapour is lighter than dry air, so moist air behaves like warmer dry air; with no moisture (q = 0) the two are equal.
Where is virtual temperature used?
In buoyancy and stability calculations, and whenever the ideal gas law is applied to moist air using the dry-air gas constant.
How does the Virtual Temperature Calculator work?
Virtual temperature of moist air: the temperature dry air would need to have the same density, Tv = T(1 + 0.61q), with q the specific humidity in g/kg. Temperature · Specific humidity → Virtual temperature. The result updates as you type, and the formula and method on this page state the exact definitions used, so you can reproduce the calculation by hand.
What inputs does the Virtual Temperature Calculator need?
Temperature · Specific humidity → Virtual temperature. Invalid entries — such as a zero denominator, an out-of-range value or a malformed list — produce a plain-language message instead of a misleading number.