Biot Number Calculator
Biot number Bi = h·L_c/k: compares surface convection with conduction inside a solid. Bi below about 0.1 means the lumped-capacitance method is valid.
What this calculator does
Biot number Bi = h·L_c/k: compares surface convection with conduction inside a solid. Bi below about 0.1 means the lumped-capacitance method is valid. Where a measure is involved, US and metric units are both accepted — flip the unit toggle and the figures convert with the same definitions the formula uses. Every result on this page is computed from the formula stated below, with no hidden rounding steps.
The formula and method
The Biot number is the ratio of internal conduction resistance to surface convection resistance: Bi = h·L_c/k, where the characteristic length L_c = V/A_s for the body.
If Bi < 0.1 the temperature inside the solid is nearly uniform during heating or cooling, and the lumped-capacitance (Newton's-law) model applies.
Worked example
With the example inputs this page opens with (surface coefficient h (w/(m²·k)) 50, characteristic length l_c (m) 0.01, solid conductivity k (w/(m·k)) 15), the result is 0.03 — biot number bi. Computed from the inputs on this page with the formula below — change any figure and every result updates.
Quick reference
| Surface coefficient h (W/(m²·K)) | Biot number Bi |
|---|---|
| 25 | 0.02 |
| 40 | 0.03 |
| 50 | 0.03 |
| 62.5 | 0.04 |
| 75 | 0.05 |
| 100 | 0.07 |
Computed with the same formulas as the calculator above — enter any values there for figures beyond this table.
Common questions
Why 0.1 as the lumped-capacitance limit?
Below Bi ≈ 0.1 the internal temperature differences stay under about 5% of the surface-to-fluid difference, so treating the body as one temperature costs little accuracy.
How can Bi be reduced?
Use a smaller characteristic length (thinner body), a more conductive solid, or gentler surface convection (lower h).
How does the Biot Number Calculator work?
Biot number Bi = h·L_c/k: compares surface convection with conduction inside a solid. Bi below about 0.1 means the lumped-capacitance method is valid. Coefficient h · Characteristic length · Conductivity → Biot number. The result updates as you type, and the formula and method on this page state the exact definitions used, so you can reproduce the calculation by hand.
What inputs does the Biot Number Calculator need?
Coefficient h · Characteristic length · Conductivity → Biot number. Invalid entries — such as a zero denominator, an out-of-range value or a malformed list — produce a plain-language message instead of a misleading number.