Vapor Pressure Deficit Calculator
Vapour pressure deficit: how far the air is from saturation, VPD = SVP × (1 − RH/100), with the saturation pressure from the Magnus formula. Key for greenhouse and plant work.
What this calculator does
Vapour pressure deficit: how far the air is from saturation, VPD = SVP × (1 − RH/100), with the saturation pressure from the Magnus formula. Key for greenhouse and plant work. Where a measure is involved, US and metric units are both accepted — flip the unit toggle and the figures convert with the same definitions the formula uses. Every result on this page is computed from the formula stated below, with no hidden rounding steps.
The formula and method
Saturation vapour pressure e_s comes from the Magnus formula e_s = 6.112·exp(17.67·T/(T+243.5)) hPa.
The deficit is the gap between saturation and the actual vapour pressure: VPD = e_s·(1 − RH/100). Growers typically target roughly 0.8–1.2 kPa for many greenhouse crops.
Worked example
With the example inputs this page opens with (air temperature t (°c) 25, relative humidity rh (%) 60), the result is 12.67 hPa — vapour pressure deficit. Computed from the inputs on this page with the formula below — change any figure and every result updates.
Quick reference
| Air temperature T (°C) | Vapour pressure deficit |
|---|---|
| 12.5 | 5.79 hPa |
| 20 | 9.35 hPa |
| 25 | 12.67 hPa |
| 31.25 | 18.24 hPa |
| 37.5 | 25.84 hPa |
| 50 | 49.61 hPa |
Computed with the same formulas as the calculator above — enter any values there for figures beyond this table.
Common questions
Why use VPD instead of relative humidity?
Plants respond to the actual drying power of the air, which combines temperature and humidity; the same RH at two temperatures gives very different VPD.
What VPD means saturated air?
Zero: at 100% relative humidity the deficit vanishes and no net evaporation occurs.
How does the Vapor Pressure Deficit Calculator work?
Vapour pressure deficit: how far the air is from saturation, VPD = SVP × (1 − RH/100), with the saturation pressure from the Magnus formula. Key for greenhouse and plant work. Temperature · Relative humidity → VPD. The result updates as you type, and the formula and method on this page state the exact definitions used, so you can reproduce the calculation by hand.
What inputs does the Vapor Pressure Deficit Calculator need?
Temperature · Relative humidity → VPD. Invalid entries — such as a zero denominator, an out-of-range value or a malformed list — produce a plain-language message instead of a misleading number.