Home · Science · Heat & Thermodynamics · Coefficient of Performance Calculator

Coefficient of Performance Calculator

Coefficient of performance of a refrigerator and a heat pump from the heat moved and the work consumed: COP_R = Q_cold/W and COP_HP = Q_hot/W = COP_R + 1.

Your figures

Example result — edit the figures to make it yours

5

COP, refrigerator

Computed from the inputs on this page with the formula below — change any figure and every result updates.

COP, heat pump6.00
Heat delivered Q_h600.00 kJ

What this calculator does

Coefficient of performance of a refrigerator and a heat pump from the heat moved and the work consumed: COP_R = Q_cold/W and COP_HP = Q_hot/W = COP_R + 1. Where a measure is involved, US and metric units are both accepted — flip the unit toggle and the figures convert with the same definitions the formula uses. Every result on this page is computed from the formula stated below, with no hidden rounding steps.

The formula and method

COP_R = Q_c/W; COP_HP = (Q_c + W)/W = COP_R + 1

A refrigerator's COP is the heat removed from the cold space per unit work: COP_R = Q_c/W.

A heat pump delivers the removed heat plus the work input, Q_h = Q_c + W, so its COP is exactly one higher: COP_HP = COP_R + 1. Heat and work must be in the same units.

Worked example

With the example inputs this page opens with (heat removed from cold space q_c (kj) 500, work input w (kj) 100), the result is 5.00 — cop, refrigerator. Computed from the inputs on this page with the formula below — change any figure and every result updates.

Quick reference

Quick reference — varying heat removed from cold space q_c (kj)
Heat removed from cold space Q_c (kJ)COP, refrigerator
2502.50
4004.00
5005.00
6256.25
7507.50
100010.00

Computed with the same formulas as the calculator above — enter any values there for figures beyond this table.

Common questions

Why can a COP be greater than 1 when efficiency cannot?

A COP counts heat moved, not energy converted: the machine transfers existing heat rather than creating it, so moving 5 kJ with 1 kJ of work is perfectly legal.

What COP do real heat pumps reach?

Typically 3–5 for home heating in mild weather, falling as the outdoor temperature drops.

How does the Coefficient of Performance Calculator work?

Coefficient of performance of a refrigerator and a heat pump from the heat moved and the work consumed: COP_R = Q_cold/W and COP_HP = Q_hot/W = COP_R + 1. Heat removed · Work input → COP (refrigerator & heat pump). The result updates as you type, and the formula and method on this page state the exact definitions used, so you can reproduce the calculation by hand.

What inputs does the Coefficient of Performance Calculator need?

Heat removed · Work input → COP (refrigerator & heat pump). Invalid entries — such as a zero denominator, an out-of-range value or a malformed list — produce a plain-language message instead of a misleading number.