Available net positive suction head at a pump inlet: atmospheric head minus vapour head, plus static head, minus friction.

Your figures

Example result — edit the figures to make it yours

12.09 m

Available NPSH

Computed from the inputs on this page with the formula below — change any figure and every result updates.

Pressure head term10.09 m

What this calculator does

Available net positive suction head at a pump inlet: atmospheric head minus vapour head, plus static head, minus friction. Where a measure is involved, US and metric units are both accepted — flip the unit toggle and the figures convert with the same definitions the formula uses. Every result on this page is computed from the formula stated below, with no hidden rounding steps.

The formula and method

NPSHa = (p_atm − p_vap) / (ρ · g) + h_static − h_friction

All terms are heads in metres: the pressure term converts (atmospheric − vapour) pressure to metres of the pumped liquid using g = 9.80665 m/s² and water at 1000 kg/m³ by default.

NPSHa must exceed the pump's required NPSH (NPSHr) with margin, or the inlet cavitates.

Worked example

With the example inputs this page opens with (atmospheric pressure (pa) 101325, vapour pressure (pa) 2337, liquid density (kg/m³) 1000, static suction head (m) 3), the result is 12.09 m — available npsh. Computed from the inputs on this page with the formula below — change any figure and every result updates.

Quick reference

Quick reference — varying atmospheric pressure (pa)
Atmospheric pressure (Pa)Available NPSH
50662.56.93 m
8106010.03 m
10132512.09 m
126656.2514.68 m
151987.517.26 m
20265022.43 m

Computed with the same formulas as the calculator above — enter any values there for figures beyond this table.

Common questions

What happens if NPSHa is too low?

The liquid boils locally at the impeller eye (cavitation): vapour bubbles collapse downstream, causing noise, vibration, pitting and a sharp drop in pump performance.

Why does hot water need more NPSH?

Vapour pressure rises steeply with temperature, shrinking the (p_atm − p_vap) margin — near boiling, almost the whole atmospheric head is consumed.

How does the NPSH Calculator work?

Available net positive suction head at a pump inlet: atmospheric head minus vapour head, plus static head, minus friction. Pressures · Density · Static head · Friction head → NPSHa. The result updates as you type, and the formula and method on this page state the exact definitions used, so you can reproduce the calculation by hand.

What inputs does the NPSH Calculator need?