Home · Science · Heat & Thermodynamics · Heat Transfer Coefficient Calculator
Heat Transfer Coefficient Calculator
The convective heat transfer coefficient from a measured heat rate: h = Q̇/(A·ΔT). Typical values run from about 5 W/(m²·K) for still air to thousands for boiling water.
What this calculator does
The convective heat transfer coefficient from a measured heat rate: h = Q̇/(A·ΔT). Typical values run from about 5 W/(m²·K) for still air to thousands for boiling water. Where a measure is involved, US and metric units are both accepted — flip the unit toggle and the figures convert with the same definitions the formula uses. Every result on this page is computed from the formula stated below, with no hidden rounding steps.
The formula and method
Newton's law of cooling for a surface, Q̇ = h·A·ΔT, rearranged to h = Q̇/(A·ΔT).
h is not a material property: it depends on the fluid, its speed and the geometry, which is why it is usually found from experiment or correlations.
Worked example
With the example inputs this page opens with (heat transfer rate q̇ (w) 800, surface area a (m²) 10, surface–fluid δt (k) 20), the result is 4.00 W/(m²·K) — heat transfer coefficient h. Computed from the inputs on this page with the formula below — change any figure and every result updates.
Quick reference
| Heat transfer rate Q̇ (W) | Heat transfer coefficient h |
|---|---|
| 400 | 2.00 W/(m²·K) |
| 640 | 3.20 W/(m²·K) |
| 800 | 4.00 W/(m²·K) |
| 1000 | 5.00 W/(m²·K) |
| 1200 | 6.00 W/(m²·K) |
| 1600 | 8.00 W/(m²·K) |
Computed with the same formulas as the calculator above — enter any values there for figures beyond this table.
Common questions
What are typical h values?
Natural convection in air 5–25, forced air 25–250, flowing water 500–10,000, and boiling or condensing fluids higher still, all in W/(m²·K).
Why does h rise with flow speed?
Faster flow thins the slow-moving boundary layer next to the surface, and that layer is the main resistance to heat transfer.
How does the Heat Transfer Coefficient Calculator work?
The convective heat transfer coefficient from a measured heat rate: h = Q̇/(A·ΔT). Typical values run from about 5 W/(m²·K) for still air to thousands for boiling water. Heat rate · Area · ΔT → Coefficient h. The result updates as you type, and the formula and method on this page state the exact definitions used, so you can reproduce the calculation by hand.
What inputs does the Heat Transfer Coefficient Calculator need?
Heat rate · Area · ΔT → Coefficient h. Invalid entries — such as a zero denominator, an out-of-range value or a malformed list — produce a plain-language message instead of a misleading number.