Home · Science · Fluid Mechanics · Fan Calculator (Fan Laws)

Fan Calculator (Fan Laws)

The fan affinity laws: how flow, pressure and power of a fan or pump change when its speed changes.

Your figures

Example result — edit the figures to make it yours

12 m³/s

New flow rate

Computed from the inputs on this page with the formula below — change any figure and every result updates.

New pressure720.00 Pa
New power8,640.00 W

What this calculator does

The fan affinity laws: how flow, pressure and power of a fan or pump change when its speed changes. Where a measure is involved, US and metric units are both accepted — flip the unit toggle and the figures convert with the same definitions the formula uses. Every result on this page is computed from the formula stated below, with no hidden rounding steps.

The formula and method

Q ∝ N, p ∝ N², P ∝ N³ (fan affinity laws)

Fan laws for the same fan and fluid: flow scales with speed, pressure with speed squared, power with speed cubed.

The cubic power law is why slowing a fan slightly saves so much energy — a 20% speed cut nearly halves the power.

Worked example

With the example inputs this page opens with (base flow rate (m³/s) 10, base pressure (pa) 500, base power (w) 5000, base speed (rpm) 1000), the result is 12.00 m³/s — new flow rate. Computed from the inputs on this page with the formula below — change any figure and every result updates.

Quick reference

Quick reference — varying base flow rate (m³/s)
Base flow rate (m³/s)New flow rate
56.00 m³/s
89.60 m³/s
1012.00 m³/s
12.515.00 m³/s
1518.00 m³/s
2024.00 m³/s

Computed with the same formulas as the calculator above — enter any values there for figures beyond this table.

Common questions

Do the fan laws hold for pumps too?

Yes — the same affinity laws apply to centrifugal pumps: flow with speed, head with speed squared, power with speed cubed, at the corresponding duty point.

When do the fan laws break down?

Across large speed changes, with density changes (altitude, temperature), or when the system resistance curve shifts — for example with dampers moving as well.

How does the Fan Calculator (Fan Laws) work?

The fan affinity laws: how flow, pressure and power of a fan or pump change when its speed changes. Base duty · Old speed · New speed → New flow · Pressure · Power. The result updates as you type, and the formula and method on this page state the exact definitions used, so you can reproduce the calculation by hand.

What inputs does the Fan Calculator (Fan Laws) need?

Base duty · Old speed · New speed → New flow · Pressure · Power. Invalid entries — such as a zero denominator, an out-of-range value or a malformed list — produce a plain-language message instead of a misleading number.