Home · Science · Engineering Mechanics · Buckling Calculator

Buckling Calculator

Euler critical buckling load for a slender column, with the effective-length factor K for the standard end conditions entered as a select.

Your figures

Example result — edit the figures to make it yours

493,480.22 N

Critical buckling load

Computed from the inputs on this page with the formula below — change any figure and every result updates.

Critical buckling load493.48 kN
Effective length2,000.00 mm

What this calculator does

Euler critical buckling load for a slender column, with the effective-length factor K for the standard end conditions entered as a select. Where a measure is involved, US and metric units are both accepted — flip the unit toggle and the figures convert with the same definitions the formula uses. Every result on this page is computed from the formula stated below, with no hidden rounding steps.

The formula and method

P_cr = π² · E · I / (K · L)²

Euler formula: valid for slender columns where P_cr/A stays below the yield strength.

K values: 0.5 fixed–fixed, 0.7 fixed–pinned, 1.0 pinned–pinned, 2.0 fixed–free.

Worked example

With the example inputs this page opens with (young's modulus (mpa) 200000, second moment of area (mm⁴) 1000000, column length (mm) 2000), the result is 493,480.22 N — critical buckling load. Computed from the inputs on this page with the formula below — change any figure and every result updates.

Quick reference

Quick reference — varying young's modulus (mpa)
Young's modulus (MPa)Critical buckling load
100000246,740.11 N
160000394,784.18 N
200000493,480.22 N
250000616,850.28 N
300000740,220.33 N
400000986,960.44 N

Computed with the same formulas as the calculator above — enter any values there for figures beyond this table.

Common questions

Which I should I use?

The second moment about the axis with the smallest radius of gyration, because the column buckles about its weakest axis first — unless bracing prevents it.

When is Euler not valid?

For short, stocky columns the critical stress exceeds yield and the column crushes instead; Johnson's parabola or the code column curves cover that range.

How does the Buckling Calculator work?

Euler critical buckling load for a slender column, with the effective-length factor K for the standard end conditions entered as a select. E (MPa) · I (mm⁴) · Length (mm) · End condition K → Critical load (N). The result updates as you type, and the formula and method on this page state the exact definitions used, so you can reproduce the calculation by hand.

What inputs does the Buckling Calculator need?

E (MPa) · I (mm⁴) · Length (mm) · End condition K → Critical load (N). Invalid entries — such as a zero denominator, an out-of-range value or a malformed list — produce a plain-language message instead of a misleading number.