Home · Everyday · Tech, Text & Media · Cable Impedance Calculator
Cable Impedance Calculator
Computes the characteristic impedance of a coaxial cable from its conductor diameters and the dielectric constant of its insulation.
What this calculator does
Computes the characteristic impedance of a coaxial cable from its conductor diameters and the dielectric constant of its insulation. Where a measure is involved, US and metric units are both accepted — flip the unit toggle and the figures convert with the same definitions the formula uses. Every result on this page is computed from the formula stated below, with no hidden rounding steps.
The formula and method
For a coaxial line, the characteristic impedance depends only on the ratio of conductor diameters and the dielectric: Z₀ = (138/√εr)·log₁₀(D/d) ohms, assuming round concentric conductors and a uniform, non-magnetic insulation. The defaults (D/d = 3.5, εr = 2.25 for PTFE-like dielectric) land at about 50 Ω, the standard RF impedance.
Because only the ratio D/d enters, any consistent length unit works. The same dielectric sets the velocity factor 1/√εr, shown alongside: signals in PTFE coax travel at about 0.67 c. Foam dielectrics lower εr toward 1.3–1.5, raising both impedance for a given geometry and the velocity factor; the formula ignores conductor losses, which matter at high frequency but barely move Z₀.
Worked example
With the example inputs this page opens with (inner conductor diameter d 1, outer conductor inner diameter d 3.5, relative permittivity εr of dielectric 2.25), the result is 50.05 Ω — characteristic impedance z₀. Computed from the inputs on this page with the formula below — change any figure and every result updates.
Quick reference
| Relative permittivity εr of dielectric | Characteristic impedance Z₀ | Velocity factor (× c) |
|---|---|---|
| 1 | 75.08139 | 1 |
| 1.5 | 61.303698 | 0.816497 |
| 2 | 53.09056 | 0.707107 |
| 2.25 | 50.05426 | 0.666667 |
| 3 | 43.348261 | 0.57735 |
| 4 | 37.540695 | 0.5 |
Computed with the same formulas as the calculator above — enter any values there for figures beyond this table.
Common questions
Why is so much coax exactly 50 Ω?
It is a historical compromise: about 30 Ω gives maximum power handling and about 77 Ω gives lowest loss in air-dielectric coax, and 50 Ω sits between the two.
How does the Cable Impedance Calculator work?
Computes the characteristic impedance of a coaxial cable from its conductor diameters and the dielectric constant of its insulation. Inner diameter d · Outer diameter D · Dielectric εr → Impedance (Ω). The result updates as you type, and the formula and method on this page state the exact definitions used, so you can reproduce the calculation by hand.
What inputs does the Cable Impedance Calculator need?
Inner diameter d · Outer diameter D · Dielectric εr → Impedance (Ω). Invalid entries — such as a zero denominator, an out-of-range value or a malformed list — produce a plain-language message instead of a misleading number.
Is the Cable Impedance Calculator free to use?
Yes. It runs entirely in your browser with no sign-up, and the same calculator is available as an embeddable widget via the Embed button, so it can be placed on another site with its calculation intact.