Home · Construction & Home DIY · Ice & Water Shield Calculator

Ice & Water Shield Calculator

Rolls of ice and water shield membrane needed along a roof's eaves, from the total eave length, the number of membrane rows, and the roll length.

Your figures

Example result — edit the figures to make it yours

2

Rolls needed

Total membrane length120 ft

What this calculator does

Rolls of ice and water shield membrane needed along a roof's eaves, from the total eave length, the number of membrane rows, and the roll length. Every figure is computed from the formula stated below. Densities, waste percentages and coverage rates appear as editable inputs with their planning defaults stated in the method notes — they are assumptions you can adjust to your supplier and your site, not industry standards.

The formula and method

Rolls = ceil(eave length · rows / roll length)

Each row of membrane runs the full eave length, so the total linear footage is the eave length times the number of rows; rolls are that length divided by the roll length, rounded up.

Rows (default 2) is an editable planning assumption: codes in cold climates typically require the membrane to extend from the eave to at least 24 in inside the wall line, which often takes two 36 in rows on steeper or deeper-overhang roofs.

Roll length (default 66.7 ft) matches a standard 200 sq ft roll at 36 in wide; check your product, as shorter 50–65 ft rolls are common.

Worked example

With the example inputs this page opens with (total eave length (ft) 60, rows of membrane 2, roll length (ft) 66.7), the result is 2 — rolls needed. Change any figure and the result updates with the same formula.

Quick reference

Quick reference — varying total eave length (ft)
Total eave length (ft)Rolls needed
301
482
602
753
903
1204

Computed with the same formulas as the calculator above — enter any values there for figures beyond this table.

Common questions

Where else does ice and water shield go?

Valleys, around penetrations, at low-slope sections and at roof-to-wall junctions commonly get a row too. Add those lengths to the eave length before using this calculator.

How far up the roof should the membrane reach?

The usual requirement is from the eave edge to a point at least 24 in inside the exterior wall line, measured along the slope. On a shallow pitch or deep overhang that can take two or even three rows.

How does the Ice & Water Shield Calculator work?

Rolls of ice and water shield membrane needed along a roof's eaves, from the total eave length, the number of membrane rows, and the roll length. Total eave length (ft) · Rows of membrane · Roll length (ft) → Rolls needed. The result updates as you type, and the formula and method on this page state every assumption used, so you can reproduce the calculation by hand.

What inputs does the Ice & Water Shield Calculator need?

Total eave length (ft) · Rows of membrane · Roll length (ft) → Rolls needed. Densities, waste percentages and coverage rates are editable — adjust them to your supplier's figures. Invalid entries produce a plain-language message instead of a misleading number.