Home · Construction & Home DIY · Heat Loss Calculator
Heat Loss Calculator
Steady heat loss of a building through walls, ceiling and windows from their areas, U-factors and the inside–outside temperature difference.
What this calculator does
Steady heat loss of a building through walls, ceiling and windows from their areas, U-factors and the inside–outside temperature difference. Every figure is computed from the formula stated below. Densities, waste percentages and coverage rates appear as editable inputs with their planning defaults stated in the method notes — they are assumptions you can adjust to your supplier and your site, not industry standards.
The formula and method
Each surface loses U × A × ΔT; the outputs sum the three surfaces you enter.
The default U-factors (walls 0.07, ceiling 0.05, windows 0.5 BTU/hr·ft²·°F) are typical planning values for insulated construction and single/double glazing respectively — edit them to your assemblies; they are assumptions, not measurements of your building.
Infiltration, floors on grade and thermal bridges are not included, so treat the result as the fabric-loss component of a heating load.
Worked example
With the example inputs this page opens with (wall area (sq ft) 800, ceiling area (sq ft) 1000, window area (sq ft) 120, temperature difference δt (°f) 40), the result is 6,640 — total heat loss. Change any figure and the result updates with the same formula.
Quick reference
| Temperature difference ΔT (°F) | Total heat loss |
|---|---|
| 10 | 1660 |
| 20 | 3320 |
| 30 | 4980 |
| 40 | 6640 |
| 50 | 8300 |
| 60 | 9960 |
Computed with the same formulas as the calculator above — enter any values there for figures beyond this table.
Common questions
What ΔT should I use?
The design temperature difference: your indoor setpoint minus the local winter design outdoor temperature, so the heater is sized for a cold night, not an average one.
Why do windows dominate despite their small area?
Their U-factor is roughly seven to ten times that of an insulated wall, so each square foot of glass loses as much heat as many square feet of wall.
How does the Heat Loss Calculator work?
Steady heat loss of a building through walls, ceiling and windows from their areas, U-factors and the inside–outside temperature difference. Wall/ceiling/window areas (sq ft) · U-factors · Temperature difference (°F) → Heat loss (BTU/hr). The result updates as you type, and the formula and method on this page state every assumption used, so you can reproduce the calculation by hand.
What inputs does the Heat Loss Calculator need?
Wall/ceiling/window areas (sq ft) · U-factors · Temperature difference (°F) → Heat loss (BTU/hr). Densities, waste percentages and coverage rates are editable — adjust them to your supplier's figures. Invalid entries produce a plain-language message instead of a misleading number.